[{"data":1,"prerenderedAt":664},["ShallowReactive",2],{"doc-\u002Fpression-chaudiere":3,"related-\u002Fpression-chaudiere":571},{"kind":4,"article":5},"article",{"id":6,"title":7,"affiliate":8,"author":9,"body":10,"budget":488,"category":489,"date":490,"description":491,"draft":8,"duration":492,"extension":493,"faq":494,"image":513,"imageAlt":514,"imageCredit":515,"level":518,"meta":519,"navigation":520,"path":521,"pinTitle":522,"products":523,"readingTime":524,"reviewedBy":525,"seo":526,"seoTitle":527,"sources":528,"sponsored":8,"stem":544,"steps":545,"updated":490,"__hash__":570},"articles\u002F2026-10-12-pression-chaudiere.md","Pression de chaudière trop basse ou trop haute : la remettre à niveau en 5 minutes",false,"La rédaction",{"type":11,"value":12,"toc":472},"minimark",[13,22,25,64,69,76,170,177,184,188,195,202,213,217,224,228,240,244,255,315,320,327,331,334,337,341,348,351,373,380,384,416,420,427,434,442,446],[14,15,16,17,21],"p",{},"Le premier matin froid, vous rallumez le chauffage et rien ne se passe : radiateurs froids, chaudière en défaut, un code qui clignote. Dans bien des cas, le coupable tient dans un petit cadran sous l'appareil. ",[18,19,20],"strong",{},"La pression de la chaudière"," est tombée sous son seuil de fonctionnement, et l'appareil s'est mis en sécurité.",[14,23,24],{},"La bonne nouvelle : remettre de la pression prend cinq minutes, sans outil. La mauvaise : une pression qui baisse toute seule, ou qui grimpe jusqu'à 3 bars, ne se règle pas en tournant un robinet. Voici comment lire le manomètre, remettre à niveau, et reconnaître les trois pannes qui justifient d'appeler un chauffagiste.",[26,27,30],"callout",{"title":28,"type":29},"La réponse courte","tip",[31,32,33,40,46,52,58],"ul",{},[34,35,36,39],"li",{},[18,37,38],{},"Pression normale à froid : 1 à 1,5 bar"," pour la plupart des chaudières murales, un peu plus dans une maison à étages. La notice donne la valeur exacte.",[34,41,42,45],{},[18,43,44],{},"À chaud, jusqu'à 2 bars environ, c'est normal"," : l'eau se dilate en chauffant.",[34,47,48,51],{},[18,49,50],{},"Sous 1 bar à froid",", remettez de l'eau par le robinet de remplissage, doucement, et refermez à la bonne valeur.",[34,53,54,57],{},[18,55,56],{},"À 3 bars, la soupape de sécurité s'ouvre"," : purgez un radiateur pour redescendre, puis cherchez la cause.",[34,59,60,63],{},[18,61,62],{},"Plus de deux appoints d'eau dans la saison"," : il y a une fuite ou un vase d'expansion à faire vérifier par un professionnel.",[65,66,68],"h2",{"id":67},"quelle-est-la-bonne-pression-pour-une-chaudière","Quelle est la bonne pression pour une chaudière ?",[14,70,71,72,75],{},"Le circuit de chauffage est une boucle fermée remplie d'eau. La chaudière a besoin d'une certaine pression pour faire circuler cette eau jusqu'au radiateur le plus éloigné et le plus haut : selon Vaillant, une pression trop faible empêche la chaleur d'atteindre les radiateurs éloignés ou situés à l'étage. Selon Vaillant et ENGIE, la plage habituelle se situe ",[18,73,74],{},"entre 1 et 1,5 bar à froid",".",[77,78,79,95],"table",{},[80,81,82],"thead",{},[83,84,85,89,92],"tr",{},[86,87,88],"th",{},"Lecture du manomètre, chauffage froid",[86,90,91],{},"Ce que cela signifie",[86,93,94],{},"Que faire",[96,97,98,110,121,137,148,159],"tbody",{},[83,99,100,104,107],{},[101,102,103],"td",{},"Moins de 0,5 bar",[101,105,106],{},"Circuit presque vide, chaudière souvent en sécurité",[101,108,109],{},"Remettre en eau, puis chercher la fuite",[83,111,112,115,118],{},[101,113,114],{},"0,5 à 1 bar",[101,116,117],{},"Un peu bas : radiateurs d'étage tièdes, bruits de circulation",[101,119,120],{},"Compléter jusqu'à la valeur de la notice",[83,122,123,128,134],{},[101,124,125],{},[18,126,127],{},"1 à 1,5 bar",[101,129,130,133],{},[18,131,132],{},"Plage normale"," (plain-pied ou appartement)",[101,135,136],{},"Rien",[83,138,139,142,145],{},[101,140,141],{},"1,5 à 2 bars",[101,143,144],{},"Normal dans une maison à étages, un peu haut ailleurs",[101,146,147],{},"Vérifier la notice",[83,149,150,153,156],{},[101,151,152],{},"Plus de 2 bars à froid",[101,154,155],{},"Trop rempli",[101,157,158],{},"Purger un radiateur pour redescendre",[83,160,161,164,167],{},[101,162,163],{},"Proche de 3 bars à chaud",[101,165,166],{},"Soupape de sécurité sur le point de s'ouvrir",[101,168,169],{},"Faire baisser, puis chercher la cause",[14,171,172,173,176],{},"Pourquoi plus de pression dans une maison à étages ? Parce que l'eau pèse. ENGIE rappelle que la pression baisse d'",[18,174,175],{},"environ 1 bar pour 10 mètres de hauteur",". Si le radiateur le plus haut se trouve 8 mètres au-dessus d'une chaudière installée au sous-sol, il faut environ 1,2 bar au départ pour que l'eau y arrive avec assez de pression.",[26,178,181],{"title":179,"type":180},"Lisez toujours la pression à froid","info",[14,182,183],{},"La pression d'un circuit monte quand l'eau chauffe. Une lecture de 1,8 bar pendant que les radiateurs sont brûlants peut correspondre à 1,2 bar le lendemain matin. Pour comparer d'un jour à l'autre, lisez le manomètre à la même heure, chauffage arrêté depuis au moins une heure.",[65,185,187],{"id":186},"pourquoi-la-pression-monte-quand-on-chauffe","Pourquoi la pression monte quand on chauffe",[14,189,190,191,194],{},"L'eau se dilate en chauffant. Entre 10 °C et 70 °C, son volume augmente d'environ 2 % (sa masse volumique passe d'environ 999,7 à 977,8 kg\u002Fm³). Sur un circuit de 100 litres, cela fait ",[18,192,193],{},"2 litres d'eau en plus"," à loger dans des tuyaux qui, eux, ne grandissent pas.",[14,196,197,198,201],{},"C'est le rôle du ",[18,199,200],{},"vase d'expansion",", un réservoir rond ou plat caché dans la chaudière ou fixé à côté. À l'intérieur, une membrane sépare l'eau du circuit d'un coussin d'air ou d'azote sous pression. Quand l'eau se dilate, elle comprime ce coussin ; quand elle refroidit, le coussin la repousse dans le circuit. Résultat : la pression ne varie que de quelques dixièmes de bar entre froid et chaud.",[14,203,204,205,208,209,212],{},"Et si cela ne suffit pas, la ",[18,206,207],{},"soupape de sécurité"," prend le relais. Tarée à ",[18,210,211],{},"3 bars",", elle s'ouvre et laisse s'échapper le surplus d'eau par un petit tuyau d'évacuation, en général raccordé à un entonnoir sous la chaudière.",[65,214,216],{"id":215},"remettre-de-la-pression-la-méthode-en-5-minutes","Remettre de la pression : la méthode en 5 minutes",[14,218,219,220,223],{},"Le robinet de remplissage est presque toujours sous la chaudière, sur l'arrivée d'eau froide. Sa forme varie selon les marques : petite manette bleue chez certains fabricants, molette noire chez d'autres, ou deux robinets reliés par un flexible amovible. La notice le montre sur un schéma. Ouvrez-le ",[18,221,222],{},"lentement"," : une ouverture brutale fait monter la pression en quelques secondes, et vous risquez de dépasser la cible.",[225,226],"step-list",{"title":227},"Remettre la chaudière en pression",[26,229,232],{"title":230,"type":231},"Ce qu'il ne faut jamais faire","warning",[14,233,234,235,75],{},"N'ouvrez jamais le capot de la chaudière et ne touchez ni au robinet de gaz ni aux réglages du brûleur : c'est le travail d'un professionnel qualifié. Ne bouchez pas le tuyau de la soupape de sécurité, même s'il goutte. Et si vous sentez une odeur de gaz, n'actionnez aucun interrupteur, aérez, sortez et appelez le numéro d'urgence gaz depuis l'extérieur. Une chaudière qui se met en sécurité à répétition, des maux de tête ou des nausées dans la pièce doivent aussi faire penser au ",[236,237,239],"a",{"href":238},"\u002Fmonoxyde-de-carbone-signes","monoxyde de carbone",[65,241,243],{"id":242},"la-pression-baisse-sans-arrêt-les-4-causes","La pression baisse sans arrêt : les 4 causes",[14,245,246,247,250,251,254],{},"Une pression qui baisse une fois, après une purge, n'a rien d'inquiétant. Une pression qui baisse ",[18,248,249],{},"toute seule",", semaine après semaine, signifie que de l'eau sort du circuit, ou que le vase d'expansion ne fait plus son travail. Selon ENGIE, au-delà de ",[18,252,253],{},"deux appoints d'eau dans la même saison de chauffe",", il faut faire venir un professionnel.",[77,256,257,270],{},[80,258,259],{},[83,260,261,264,267],{},[86,262,263],{},"Ce que vous observez",[86,265,266],{},"Cause probable",[86,268,269],{},"Qui intervient",[96,271,272,283,294,305],{},[83,273,274,277,280],{},[101,275,276],{},"Baisse juste après avoir purgé les radiateurs",[101,278,279],{},"Eau sortie par les purgeurs, rien d'anormal",[101,281,282],{},"Vous : remettre à niveau",[83,284,285,288,291],{},[101,286,287],{},"Baisse lente, régulière, sans purge",[101,289,290],{},"Petite fuite : raccord de radiateur, robinet, tuyau, joint",[101,292,293],{},"Vous pour chercher, un pro si elle est cachée",[83,295,296,299,302],{},[101,297,298],{},"Trace d'eau ou calcaire sous la chaudière, entonnoir humide",[101,300,301],{},"Soupape de sécurité qui goutte",[101,303,304],{},"Un professionnel",[83,306,307,310,313],{},[101,308,309],{},"Pression qui grimpe vers 3 bars à chaud et s'effondre à froid",[101,311,312],{},"Vase d'expansion dégonflé ou membrane percée",[101,314,304],{},[316,317,319],"h3",{"id":318},"chercher-une-petite-fuite","Chercher une petite fuite",[14,321,322,323,326],{},"Une fuite de chauffage est rarement spectaculaire. Quelques gouttes par heure suffisent à vider un circuit en quelques semaines, et l'eau chaude s'évapore avant de faire une flaque. Passez un essuie-tout sec sous chaque radiateur, au niveau des robinets, des raccords et du purgeur. Cherchez des ",[18,324,325],{},"traces blanches ou rouille"," sur les raccords, une tache sur le parquet, une auréole au plafond sous un tuyau. Vérifiez aussi le purgeur que vous avez ouvert en dernier : mal refermé, il suinte.",[316,328,330],{"id":329},"le-vase-dexpansion-dégonflé","Le vase d'expansion dégonflé",[14,332,333],{},"C'est la panne la plus trompeuse, car elle combine les deux symptômes. Le coussin d'air du vase se vide lentement avec les années. L'eau qui se dilate ne trouve plus de place : la pression grimpe à chaque chauffe, la soupape s'ouvre et évacue un peu d'eau. Au refroidissement, il manque cette eau, et la pression tombe très bas. Vous remettez de l'eau, et le cycle recommence.",[14,335,336],{},"Le diagnostic et le regonflage du vase se font circuit vidangé ou isolé, avec un manomètre adapté : c'est une intervention de chauffagiste, souvent réalisée lors de l'entretien annuel. Si le vase est percé, il se remplace.",[65,338,340],{"id":339},"pression-trop-haute-comment-la-faire-baisser","Pression trop haute : comment la faire baisser ?",[14,342,343,344,347],{},"Une pression trop élevée à froid vient le plus souvent d'un remplissage trop généreux, ou d'un ",[18,345,346],{},"robinet de remplissage mal fermé"," qui laisse passer l'eau du réseau, bien plus pressurisée que le circuit de chauffage.",[14,349,350],{},"Pour redescendre, chauffage arrêté et refroidi :",[352,353,354,360,363,370],"ol",{},[34,355,356,357,75],{},"Vérifiez d'abord que le robinet de remplissage est ",[18,358,359],{},"bien fermé",[34,361,362],{},"Placez un récipient et un chiffon sous le purgeur d'un radiateur, de préférence au rez-de-chaussée.",[34,364,365,366,75],{},"Ouvrez le purgeur d'un quart de tour avec une clé de purge, comme pour ",[236,367,369],{"href":368},"\u002Fpurger-radiateur","purger un radiateur",[34,371,372],{},"Laissez couler l'eau en surveillant le manomètre, et refermez quand il revient vers 1 à 1,5 bar.",[14,374,375,376,379],{},"Si la pression ",[18,377,378],{},"remonte d'elle-même"," dans les heures qui suivent, alors que vous n'avez rien touché, l'eau vient d'ailleurs : robinet de remplissage qui fuit intérieurement, ou plus rarement une fuite interne de la chaudière entre le circuit d'eau chaude sanitaire et celui du chauffage. ENGIE classe ce cas parmi ceux qui justifient un professionnel.",[65,381,383],{"id":382},"les-erreurs-à-éviter","Les erreurs à éviter",[31,385,386,392,398,404,410],{},[34,387,388,391],{},[18,389,390],{},"Remettre de l'eau chaudière chaude."," La lecture est faussée par la dilatation : vous croyez être à 1,5 bar, et le lendemain matin vous êtes à 0,9.",[34,393,394,397],{},[18,395,396],{},"Ouvrir le robinet de remplissage en grand."," L'eau du réseau arrive avec plus de pression que celle du circuit : en quelques secondes, l'aiguille dépasse la cible, et vous voilà à purger pour redescendre.",[34,399,400,403],{},[18,401,402],{},"Oublier de refermer le robinet."," C'est la première cause de pression trop haute après un remplissage.",[34,405,406,409],{},[18,407,408],{},"Remettre de l'eau tous les mois sans chercher pourquoi."," Chaque appoint fait entrer de l'eau neuve chargée d'oxygène et de calcaire, qui corrode et encrasse le circuit. Une petite fuite ignorée coûte plus cher qu'une visite.",[34,411,412,415],{},[18,413,414],{},"Ignorer une soupape qui goutte."," Elle signale soit une pression trop haute, soit une soupape usée qui ne protège plus correctement.",[65,417,419],{"id":418},"lentretien-annuel-le-bon-moment-pour-en-parler","L'entretien annuel, le bon moment pour en parler",[14,421,422,423,426],{},"L'entretien des chaudières au gaz, au fioul, au bois ou au charbon de 4 à 400 kW est ",[18,424,425],{},"obligatoire chaque année",", en application du décret du 9 juin 2009. Le professionnel remet une attestation dans les 15 jours, à conserver au moins deux ans. Dans un logement loué, il est à la charge du locataire, sauf si le bail prévoit que le bailleur s'en occupe, précise service-public.gouv.fr.",[14,428,429,430,75],{},"Profitez de cette visite pour signaler vos relevés de pression : notez la valeur à froid et à chaud pendant une semaine avant le passage du chauffagiste. Ces chiffres l'orientent tout de suite vers une fuite ou vers le vase d'expansion. Pour caler cette visite dans votre calendrier avec les autres contrôles de l'automne, voyez notre ",[236,431,433],{"href":432},"\u002Fentretien-maison-checklist-saisons","check-list d'entretien de la maison saison par saison",[14,435,436,437,441],{},"Une fois le circuit en pression et purgé, il reste à régler la bonne consigne dans chaque pièce : notre guide de la ",[236,438,440],{"href":439},"\u002Ftemperature-chauffage-par-piece","température idéale pièce par pièce"," montre ce que vous coûte chaque degré.",[65,443,445],{"id":444},"en-résumé","En résumé",[31,447,448,455,466,469],{},[34,449,450,451,454],{},"Lisez la pression ",[18,452,453],{},"à froid"," : 1 à 1,5 bar en général, la notice fait foi.",[34,456,457,458,461,462,465],{},"Pour remettre de l'eau, ouvrez ",[18,459,460],{},"doucement"," le robinet de remplissage et ",[18,463,464],{},"refermez"," à la bonne valeur.",[34,467,468],{},"À chaud, jusqu'à 2 bars environ est normal ; à 3 bars, la soupape s'ouvre.",[34,470,471],{},"Une pression qui baisse sans purge, qui fait le yoyo ou qui remonte seule : fuite, vase d'expansion ou robinet de remplissage, à faire vérifier par un chauffagiste.",{"title":473,"searchDepth":474,"depth":474,"links":475},"",2,[476,477,478,479,484,485,486,487],{"id":67,"depth":474,"text":68},{"id":186,"depth":474,"text":187},{"id":215,"depth":474,"text":216},{"id":242,"depth":474,"text":243,"children":480},[481,483],{"id":318,"depth":482,"text":319},3,{"id":329,"depth":482,"text":330},{"id":339,"depth":474,"text":340},{"id":382,"depth":474,"text":383},{"id":418,"depth":474,"text":419},{"id":444,"depth":474,"text":445},"Rien : l'eau du réseau suffit","reparations","2026-10-12","Pression chaudière : 1 à 1,5 bar à froid, 3 bars ouvre la soupape. Remettre de l'eau pas à pas, et trouver pourquoi la pression baisse ou monte toute seule.","5 minutes pour remettre en pression","md",[495,498,501,504,507,510],{"q":496,"a":497},"Quelle est la pression normale d'une chaudière ?","À froid, la plupart des chaudières murales fonctionnent entre 1 et 1,5 bar, selon Vaillant et ENGIE. En fonctionnement, l'eau chaude se dilate et la pression monte, jusqu'à 2 bars environ. Dans une maison à étages, il faut un peu plus de pression : environ 1 bar de plus pour 10 mètres de hauteur à alimenter. La valeur exacte de votre appareil figure dans sa notice.",{"q":499,"a":500},"Pourquoi la pression de ma chaudière baisse-t-elle ?","Après une purge de radiateurs, c'est normal : de l'eau est sortie du circuit. Sans purge, une baisse régulière signale presque toujours une petite fuite (raccord de radiateur, robinet, soupape qui goutte) ou un vase d'expansion dégonflé. Si vous devez remettre de l'eau plus de deux fois dans la saison, ENGIE conseille de faire venir un professionnel.",{"q":502,"a":503},"Une chaudière à 3 bars, est-ce dangereux ?","La chaudière est protégée : à 3 bars, sa soupape de sécurité s'ouvre et évacue l'excès d'eau. Ce n'est donc pas une explosion qui menace, mais c'est le signe d'un problème : circuit trop rempli, robinet de remplissage qui fuit ou vase d'expansion défaillant. Faites baisser la pression en purgeant un radiateur, puis cherchez la cause.",{"q":505,"a":506},"Comment faire baisser la pression d'une chaudière ?","Chauffage arrêté et refroidi, ouvrez le purgeur d'un radiateur avec une clé de purge, un récipient et un chiffon dessous. Laissez couler l'eau en surveillant le manomètre, et refermez quand il revient vers 1 à 1,5 bar. Si la pression remonte ensuite toute seule, le robinet de remplissage ou la chaudière doit être vérifié par un chauffagiste.",{"q":508,"a":509},"La pression monte quand le chauffage tourne : est-ce normal ?","Oui, dans une certaine mesure. L'eau se dilate en chauffant et le vase d'expansion absorbe ce surplus. Passer de 1,2 bar à froid à 1,5 ou 2 bars à chaud est courant. Si l'aiguille approche les 3 bars à chaque cycle, puis redescend très bas à froid, le vase d'expansion ne joue plus son rôle : il doit être contrôlé et regonflé par un professionnel.",{"q":511,"a":512},"Le locataire doit-il s'occuper de la pression de la chaudière ?","Remettre de l'eau quand la pression est basse fait partie de l'usage normal de l'appareil, comme la purge. L'entretien annuel de la chaudière par un professionnel qualifié est à la charge du locataire, sauf si le bail prévoit que le bailleur s'en occupe, rappelle service-public.gouv.fr. Une fuite ou une pièce défaillante (vase d'expansion, soupape) se signale au propriétaire.","\u002Fimg\u002Fpression-chaudiere.webp","Manomètre à aiguille de chauffage gradué de 0 à 4, aiguille vers 1,5, relié à deux flexibles tressés",{"name":516,"url":517},"Ann Ann","https:\u002F\u002Funsplash.com\u002Fphotos\u002Fa-close-up-of-a-pressure-gauge-attached-to-a-pipe-EYYRtpYuvEU","Débutant",{},true,"\u002Fpression-chaudiere","Pression de chaudière : la bonne valeur",[],8,null,{"title":7,"description":491},"Pression chaudière trop basse ou trop haute : que faire ?",[529,532,535,538,541],{"title":530,"url":531},"Vaillant : faible pression d'eau dans une chaudière à gaz","https:\u002F\u002Fwww.vaillant.fr\u002Fconseils\u002Fcentre-d-aide\u002Ffaible-pression-d-eau-dans-une-chaudiere-a-gaz\u002F",{"title":533,"url":534},"ENGIE : quelle est la pression idéale pour votre chaudière ?","https:\u002F\u002Fparticuliers.engie.fr\u002Feconomies-energie\u002Fconseils-equipements-chauffage\u002Fconseils-chaudiere\u002Fpression-chaudiere.html",{"title":536,"url":537},"ENGIE : pression de chaudière qui baisse, que faire ?","https:\u002F\u002Fparticuliers.engie.fr\u002Feconomies-energie\u002Fconseils-equipements-chauffage\u002Fconseils-chaudiere\u002Fchaudiere-baisse-pression.html",{"title":539,"url":540},"Service-public.gouv.fr : entretien annuel de la chaudière, quelles règles pour le locataire ?","https:\u002F\u002Fwww.service-public.gouv.fr\u002Fparticuliers\u002Fvosdroits\u002FF20760",{"title":542,"url":543},"Légifrance : décret n° 2009-649 du 9 juin 2009 relatif à l'entretien annuel des chaudières","https:\u002F\u002Fwww.legifrance.gouv.fr\u002Fjorf\u002Fid\u002FJORFTEXT000020723245","2026-10-12-pression-chaudiere",[546,550,554,558,562,566],{"name":547,"duration":548,"detail":549},"Arrêter le chauffage et lire le manomètre","1 h de refroidissement","La pression se lit à froid : coupez le chauffage, attendez que les radiateurs soient tièdes, puis lisez le manomètre (cadran à aiguille ou affichage numérique en bar). Notez la valeur et cherchez dans la notice, ou sur l'étiquette de la chaudière, la pression de service recommandée.",{"name":551,"duration":552,"detail":553},"Repérer le robinet de remplissage","2 min","Il se trouve sous la chaudière, sur l'arrivée d'eau froide : souvent une petite manette ou molette bleue ou noire, parfois deux robinets reliés par un flexible ou un disconnecteur. En cas de doute, la notice le montre sur un schéma. Ne touchez jamais au robinet de gaz, qui porte en général une manette jaune.",{"name":555,"duration":556,"detail":557},"Ouvrir doucement","1 min","Tournez le robinet lentement, d'un quart de tour, jusqu'à entendre l'eau entrer dans le circuit. L'aiguille du manomètre monte peu à peu. Gardez les yeux sur le cadran : la pression peut grimper vite.",{"name":559,"duration":560,"detail":561},"Refermer à la bonne valeur","30 s","Refermez dès que l'aiguille atteint la valeur de la notice, le plus souvent entre 1 et 1,5 bar à froid, un peu plus dans une maison à étages. Vérifiez que le robinet est bien fermé : un robinet qui laisse passer fait monter la pression jusqu'à la soupape.",{"name":563,"duration":564,"detail":565},"Purger si les radiateurs gargouillent","10 min","Si vous entendez des glouglous ou si un radiateur reste froid en haut, purgez-le, puis relisez le manomètre : la purge fait baisser la pression, il faut parfois compléter une seconde fois.",{"name":567,"duration":568,"detail":569},"Relancer et surveiller","Quelques jours","Si la chaudière s'était mise en sécurité, réarmez-la selon la notice (bouton reset ou combinaison de touches). Relancez le chauffage et notez la pression à chaud, puis le lendemain à froid. Une pression stable : c'est réglé. Une pression qui rebaisse : il y a une cause à trouver.","Koa3wnPW0_IWXSDcY7nDBWgJ1NuzpKTnhbxljah0hAg",[572,602,637],{"path":573,"title":574,"description":575,"date":576,"updated":576,"category":489,"image":577,"imageAlt":578,"affiliate":8,"level":518,"duration":579,"readingTime":580,"steps":581},"\u002Ffenetre-position-hiver","Fenêtre PVC : la « position hiver » qui arrête les courants d'air, vraie astuce ou fausse bonne idée ?","Fenêtre position hiver : à quoi servent les galets excentriques, comment les régler sans abîmer les joints, le test de la feuille et quand ne pas y toucher.","2026-10-26","\u002Fimg\u002Ffenetre-position-hiver.webp","Fenêtres oscillo-battantes en PVC blanc avec poignées dorées, fermées, devant une grille en fer forgé et un jardin","10 à 20 min par fenêtre",10,[582,586,589,592,595,598],{"name":583,"duration":584,"detail":585},"Faire le test de la feuille","3 min","Fermez la fenêtre sur une feuille de papier glissée entre l'ouvrant et le dormant, poignée en position fermée. Tirez la feuille. Si elle glisse sans résistance, le joint ne presse pas à cet endroit. Recommencez tous les 20 à 30 cm sur les quatre côtés et notez les points faibles.",{"name":587,"duration":552,"detail":588},"Repérer les galets et leur marque","Ouvrez la fenêtre en grand et regardez la tranche de l'ouvrant : les galets (ou champignons) sont les petits plots métalliques qui glissent dans les gâches du cadre quand vous tournez la poignée. Cherchez une encoche, un point ou un trait sur leur tête : c'est le repère de position.",{"name":590,"duration":552,"detail":591},"Noter la position d'origine","Prenez une photo de chaque galet avant d'y toucher. C'est votre position de référence, réglée en usine ou à la pose, à laquelle vous reviendrez au printemps ou en cas de doute.",{"name":593,"duration":552,"detail":594},"Tourner un seul galet, d'un petit cran","Avec la clé adaptée (Allen, Torx ou pince selon le modèle), tournez le galet le plus proche du point faible d'un quart de tour au maximum. Certains galets octogonaux se tournent à la main, ou se tirent puis se repositionnent.",{"name":596,"duration":552,"detail":597},"Refaire le test et vérifier la poignée","Refermez sur la feuille à cet endroit. Elle doit maintenant résister franchement sans se déchirer. La poignée doit tourner sans forcer. Si elle force nettement, revenez en arrière : la compression est trop forte.",{"name":599,"duration":600,"detail":601},"Régler les autres galets de façon homogène","5 min","Procédez de la même façon sur les galets du même côté, puis des autres côtés si besoin, toujours d'un petit cran. Une pression régulière sur tout le pourtour vaut mieux qu'un seul point très serré.",{"path":603,"title":604,"description":605,"date":606,"updated":606,"category":489,"image":607,"imageAlt":608,"affiliate":8,"level":609,"duration":610,"readingTime":611,"steps":612},"\u002Fradiateur-froid-en-bas","Radiateur froid en bas et chaud en haut : boues, équilibrage ou robinet bloqué, le diagnostic complet","Radiateur froid en bas, tiède partout ou un seul radiateur froid : le diagnostic en 5 minutes, les boues et le désembouage, l'équilibrage et le robinet bloqué.","2026-10-19","\u002Fimg\u002Fradiateur-froid-en-bas.webp","Radiateur en fonte à colonnes peint en blanc sous une fenêtre ouverte, avec son robinet en laiton sur le tuyau d'arrivée","Intermédiaire","5 min pour le diagnostic, 1 h 30 à 2 h pour rincer un radiateur",11,[613,617,620,623,627,631,634],{"name":614,"duration":615,"detail":616},"Couper le chauffage et laisser refroidir","1 h","Arrêtez la chaudière ou la pompe à chaleur et attendez que le radiateur soit froid. L'eau d'un circuit peut dépasser 60 °C : on ne démonte jamais un radiateur chaud.",{"name":618,"duration":600,"detail":619},"Fermer l'arrivée et le té de réglage","Côté arrivée, fermez le robinet. Sur un robinet thermostatique, la tête ne ferme pas complètement : retirez-la et vissez à sa place le capuchon de manœuvre, serré à fond. Côté sortie, retirez le capuchon du té de réglage et fermez-le avec une clé six pans en comptant les tours : notez le chiffre, il servira à le rouvrir exactement pareil.",{"name":621,"duration":600,"detail":622},"Préparer la vidange","Protégez le sol avec une bâche et des serpillières, placez une bassine plate sous chaque raccord. Ouvrez légèrement le purgeur en haut du radiateur pour laisser entrer l'air : l'eau s'écoulera mieux.",{"name":624,"duration":625,"detail":626},"Dévisser les raccords et vider","15 min","Desserrez l'écrou de raccord côté sortie avec une clé, en retenant le corps du robinet avec une seconde clé pour ne pas tordre le tuyau. Laissez couler, puis faites de même côté arrivée. Une eau noire confirme les boues.",{"name":628,"duration":629,"detail":630},"Décrocher et rincer à l'extérieur","30 min","Soulevez le radiateur de ses consoles, à deux pour un modèle en fonte, très lourd. Dehors, envoyez l'eau du tuyau d'arrosage par un orifice, puis par l'autre, en tapotant le radiateur avec un maillet en caoutchouc, jusqu'à ce que l'eau ressorte claire.",{"name":632,"duration":625,"detail":633},"Remonter avec des joints neufs","Raccrochez le radiateur, remplacez les joints des raccords (joint plat ou fibre selon le modèle, filasse et pâte sur un filetage conique) et serrez sans excès, toujours avec deux clés.",{"name":635,"duration":625,"detail":636},"Rouvrir, purger et remettre en pression","Rouvrez le té de réglage du nombre de tours noté, puis le robinet d'arrivée, et remettez la tête thermostatique. Purgez le radiateur, contrôlez la pression de la chaudière et complétez si besoin, puis relancez le chauffage et surveillez les raccords pendant une heure.",{"path":638,"title":639,"description":640,"date":641,"updated":641,"category":489,"image":642,"imageAlt":643,"affiliate":8,"level":518,"duration":644,"readingTime":524,"steps":645},"\u002Fodeur-egout-salle-de-bain","Odeur d'égout dans la salle de bain : les 6 causes et comment s'en débarrasser","Odeur d'égout dans la salle de bain : siphon sec ou encrassé, joint de WC, ventilation de chute, VMC, bonde de douche. Les 6 causes et la solution pour chacune.","2026-10-09","\u002Fimg\u002Fodeur-egout-salle-de-bain.webp","Bonde métallique d'un lavabo en inox vue de dessus, avec sa grille perforée","5 min à 1 h selon la cause",[646,649,652,655,658,661],{"name":647,"duration":552,"detail":648},"Remettre de l'eau dans tous les siphons","Faites couler l'eau une minute dans le lavabo, la douche, la baignoire et le bidet, et tirez la chasse. Pensez aux siphons oubliés : siphon de sol, lave-mains, douche de la chambre d'amis. Si l'odeur disparaît dans l'heure, un siphon était sec.",{"name":650,"duration":625,"detail":651},"Nettoyer le siphon du lavabo et son trop-plein","Placez une bassine dessous, dévissez le culot ou le siphon à la main, videz-le et brossez-le à l'eau chaude savonneuse. Passez un goupillon dans le trop-plein du lavabo, souvent couvert d'un dépôt malodorant. Revissez sans oublier le joint.",{"name":653,"duration":564,"detail":654},"Démonter et nettoyer la bonde de douche","Retirez la grille, puis la cloche ou la pièce qui forme la garde d'eau. Ôtez cheveux et dépôts, brossez, rincez à l'eau très chaude et remettez toutes les pièces en place : sans la cloche, la bonde ne retient plus les odeurs.",{"name":656,"duration":600,"detail":657},"Vérifier le pied du WC","Sentez au ras du sol autour de la cuvette et à l'arrière, là où elle se raccorde à l'évacuation. Une odeur localisée, une auréole ou un joint noirci signalent un joint ou une pipe de WC défectueux, à remplacer.",{"name":659,"duration":600,"detail":660},"Contrôler la VMC","Posez une feuille de papier sur la bouche d'extraction : elle doit être aspirée et rester plaquée. Si ce n'est pas le cas, nettoyez la bouche à l'eau savonneuse et vérifiez que la VMC est bien en marche.",{"name":662,"duration":600,"detail":663},"Écouter les évacuations","Tirez la chasse d'eau et écoutez le lavabo et la douche. Des glouglous ou un siphon qui se vide signalent un défaut de ventilation de la chute : faites vérifier la sortie en toiture ou installez un clapet aérateur avec l'aide d'un plombier.",1793750762152]